Timber stringers
Wood is rated with the same equation as steel and concrete. What changes is the strength: a table value multiplied by a chain of factors for moisture, size, load duration and the step from allowable stress to LRFD.
Key points
- The table value is an allowable stress. The format conversion CKF = 2.5/φ turns it into a strength: 2.94 for flexure (φ = 0.85) and 3.33 for shear (φ = 0.75).
- Load duration matters. Cλ = 0.8 at Strength I (design and legal loads) and 1.0 at Strength II (permits), because wood is weaker under long total load time.
- No impact, no service check. IM = 0 for wood, the service limit state is not required, and deflection is optional.
- Shear is checked near the support. At d from the bearing, with the live load at the lesser of 3d and L/4, using 0.50 × (0.60 VLU + VLD).
- Watch the product. Wet glulam loses 20% in bending and 12.5% in shear, and its table shear value takes 0.72 for bridge stringers. Sawn timbers over 4 in. nominal keep CM = 1.0 for bending and shear; Southern Pine 5 × 5 and larger takes no wet reduction.
- Expect low HL-93 numbers. In the trial ratings behind the LRFR manual, timber bridges averaged 0.62 times their old HS20 inventory rating. The legal-load rating decides posting.
VDOT job aids J6 (distribution for timber decks on steel beams) and J7 (timber deck on steel stringers) cover timber. J7 rates by allowable stress to the AASHTO Standard Specifications, Chapter 13, for the Virginia vehicles; methods other than LRFR are allowed at the BSIE's discretion, with the reason in the rating report. IIM-S&B-80.10 makes no changes to LRFD Section 8. VDOT IIM-S&B-86.5 pp.3, 7–8; IIM-S&B-80.10 p.8
Quick check
The same stringer is rated for a permit truck at Strength II instead of Strength I. Before any change in the load factor, its resistance…
Cλ goes from 0.8 to 1.0, so Fb and Fv go up by 1.0 / 0.8 = 1.25. A permit crossing is short; routine traffic loads the wood for much longer in total.
Load Example 1 and tick "wet service". What happens to the rating?
A 6 × 16 is over 4 in. nominal, so LRFD Table 8.4.4.3-1 keeps CM = 1.00 for bending and shear. Do the same on Example 3 (glulam) and the rating moves a lot.
A short span has deep stringers. Which check is most likely to govern?
Flexural strength grows with d², shear strength only with d, and on a short span the axles sit close to the support. See "What if the stringer is deeper?".
Sources
- FHWA-NHI 130092, LRFR participant workbook, Lesson 24 (pp. 767–790). The workbook has no numeric timber exercise (PW 24.21 points to MBE Example A4, which is not in the library), so this page has no workbook check.
- AASHTO MBE 3rd Ed., 6A.7 (timber structures), Table 6A.4.4.2.3a-1 (legal load factors).
- AASHTO LRFD BDS 8th Ed., 8.4.1 (reference design values), 8.4.4 (adjustment factors), 8.5.2.2 (resistance factors), 8.6, 8.7 (flexure, shear), Table 4.6.2.2.2a-1 (wood deck distribution), 3.6.2.3 (no dynamic allowance).
- NCHRP Web Document 28 (LRFR trial ratings), pp. 62–63.
- VDOT IIM-S&B-86.5, pp. 3, 7–8 (rating methods; job aids J6, J7); IIM-S&B-80.10, p.8.
A study aid, not a substitute for the AASHTO MBE or an agency's rating procedures. Example numbers are illustrative.