Gusset plates and connections
A truss is only as strong as its joints. For each member that frames into a gusset plate, find how wide its force spreads into the plate, then check whether the plate buckles, yields or tears and whether the bolts shear, crush the plate or slip.
Shear on a plane through the plates
The members at a joint also try to slide one part of the plate past another. Each likely plane is checked for shear on its own.
Key points
- Rate the joint member by member. For each member: the bolts (shear, bearing, slip), the plate on its Whitmore width (buckling for compression; yielding, net fracture and block shear for tension), the shear planes, and any chord splice.
- The force spreads at 30°. From the first row of bolts to the last, on each side. The Whitmore width is not cut back where it crosses another member's bolt lines.
- A compression plate is a short column. Its length is Lmid, its effective length factor 0.5, and its buckling load grows with tg³. Thin or corroded plates lose strength fast.
- Dead load dominates truss joints. Above DL/LL = 1 the resistance is cut, down to 0.90 at 6, and riveted or bolted gussets take φs = 0.90. With so much dead load, a small loss of plate costs a lot of rating.
- Rating factors are not design factors. For gusset plates the MBE uses φcg = 0.95 for buckling and φvy = φbs = 1.00 for shear yielding and block shear, higher than the LRFD design values.
- Check which bolt shear values you use. The workbook's MBE uses 0.48 and 0.38; LRFD 8th uses 0.56 and 0.45, times 0.83 for joints longer than 38 in.
VDOT job aids J14 (welded gusset plates) and J15 (splice plates and pin connections) do these ratings; J14 takes φs = 0.85 for welded truss members. Gusset plates of nonredundant steel tension members get a hands-on inspection at every NSTM inspection. VDOT IIM-S&B-86.5 p.8; IIM-S&B-27.14 p.9
Quick check
A compression diagonal's plates turn out 10% thinner than the plans show. Its rating, governed by plate buckling, drops by…
The resistance drops by about 10% (a bit more if the plate is slender), but the dead load stays, so the whole loss comes out of the part left for traffic. Load Example 1 and set tg to 0.5625 in.
You add two more rows of bolts to a member, keeping Lmid the same. What happens to the plate check?
A longer bolt group spreads the force wider: each extra row adds 2 × pitch × tan 30° to the width. With 3-in. pitch that is about 3.5 in. per row.
A tension diagonal passes every strength check but fails bolt slip at Service II. What does that mean?
Slip-critical bolts are meant not to slip under service loads. If they slip, the bolts bear on the holes and the joint still has its strength. Load Example 3 and set the hole size factor Kh to 0.85 (oversize holes).
Sources
- FHWA-NHI 130092, LRFR participant workbook, Lesson 23 (pp. 741–766); Whitmore exercise PW 23.19–23.20 (MBE Example A11, member M2).
- AASHTO MBE 3rd Ed., 6A.6.12.6 (gusset plates), 6A.6.3 resistance factors and 6A.4.2.4 system factor (MBE-3 errata pp. 22 and 9).
- AASHTO LRFD BDS 8th Ed., 6.14.2.8 (gusset plates: shear, compression, tension), 6.13.5 (connection elements), 6.13.2 (bolts), 6.5.4.2 (resistance factors).
- VDOT IIM-S&B-86.5, p.8 (job aids J14, J15); IIM-S&B-27.14, p.9 (NSTM hands-on inspection).