Sign in
LRFR · Lesson 23

Gusset plates and connections

A truss is only as strong as its joints. For each member that frames into a gusset plate, find how wide its force spreads into the plate, then check whether the plate buckles, yields or tears and whether the bolts shear, crush the plate or slip.

Shear on a plane through the plates

The members at a joint also try to slide one part of the plate past another. Each likely plane is checked for shear on its own.

Key points

WWhitmore = gauge width + 2 × (length of the bolt group) × tan 30°
  • Rate the joint member by member. For each member: the bolts (shear, bearing, slip), the plate on its Whitmore width (buckling for compression; yielding, net fracture and block shear for tension), the shear planes, and any chord splice.
  • The force spreads at 30°. From the first row of bolts to the last, on each side. The Whitmore width is not cut back where it crosses another member's bolt lines.
  • A compression plate is a short column. Its length is Lmid, its effective length factor 0.5, and its buckling load grows with tg³. Thin or corroded plates lose strength fast.
  • Dead load dominates truss joints. Above DL/LL = 1 the resistance is cut, down to 0.90 at 6, and riveted or bolted gussets take φs = 0.90. With so much dead load, a small loss of plate costs a lot of rating.
  • Rating factors are not design factors. For gusset plates the MBE uses φcg = 0.95 for buckling and φvy = φbs = 1.00 for shear yielding and block shear, higher than the LRFD design values.
  • Check which bolt shear values you use. The workbook's MBE uses 0.48 and 0.38; LRFD 8th uses 0.56 and 0.45, times 0.83 for joints longer than 38 in.
In Virginia

VDOT job aids J14 (welded gusset plates) and J15 (splice plates and pin connections) do these ratings; J14 takes φs = 0.85 for welded truss members. Gusset plates of nonredundant steel tension members get a hands-on inspection at every NSTM inspection. VDOT IIM-S&B-86.5 p.8; IIM-S&B-27.14 p.9

Quick check

A compression diagonal's plates turn out 10% thinner than the plans show. Its rating, governed by plate buckling, drops by…

You add two more rows of bolts to a member, keeping Lmid the same. What happens to the plate check?

A tension diagonal passes every strength check but fails bolt slip at Service II. What does that mean?

Sources

A study aid, not a substitute for the AASHTO MBE or an agency's rating procedures. Example numbers are illustrative; a real joint needs every member, plane and block-shear path.