Rating a simple-span steel girder
One interior girder, three kinds of truck, three checks. Strength uses moments and shears; Service II uses flange stresses, with each load on the section that carries it. On a compact girder, Service II usually governs.
Key points
- Three sections, one flange. The steel carried the wet deck alone, later dead load sees the long-term composite section (3n), and traffic sees the short-term one (n). Add the stresses, not the moments.
- Service II often governs a compact girder. The plastic strength goes well past first yield; Service II holds the flange to 0.95 Fy under 1.30 × the truck.
- Condition factor is for strength only. φc and φs multiply Rn. Service II has no φ factors, so poor condition can move the governing check from Service II to Strength I.
- Each truck has its own load factors. Design: 1.75 / 1.35 at Strength I, 1.30 / 1.00 at Service II. Legal: 1.30 to 1.45 by truck traffic at Strength I, 1.30 at Service II. Special permit: Strength II with 1.10 to 1.40 by kind of trip, Service II at 1.00.
- Shear rarely governs a rolled beam. Stocky webs reach their plastic shear; check it, but expect it to be far above flexure.
Rate the VA Type 3 and VA Type 3S2 legal trucks, the AASHTO NRL and SU4–SU7, and EV2 and EV3, besides HL-93. Poor condition uses φc = 0.90. For new or fully replaced steel superstructures on projects started after November 16, 2018, the plastic moment may not be used in the rating; for older designs only if the original design used it, with the Load Rating Program Manager's confirmation. VDOT IIM-S&B-86.5 p.3, p.5
Quick check
The inspector downgrades a steel girder from Fair to Poor (φc 1.00 → 0.90). Which rating does not change?
Service II compares stresses with 0.95 Fy and uses no φ factors. Try Example 1 and set the condition factor to Poor: Strength I drops, Service II stays at the same value.
A parapet is replaced with a heavier one (more DC2). Which rating drops faster?
Strength I takes 1.25 × the added moment out of a large plastic strength. Service II adds the stress against a fixed 0.95 Fy that dead load already uses a good part of, so it falls faster. See "What if dead load is added after the deck cures?".
In Example 1, change the kind of permit from a single trip to fewer than 100 trips. Which permit rating stays the same?
The permit type sets the Strength II load factor (1.10, 1.20 or 1.40). Service II for permits uses 1.00 whatever the permit, so it does not move.
Sources
- FHWA-NHI 130092, LRFR participant workbook, Lesson 21 (pp. 681–708); exercise PW 21.5–21.24, solution pp. 842–849 (MBE Example A1).
- AASHTO MBE 3rd Ed., 6A.4.2 (rating equation, condition and system factors), Table 6A.4.2.2-1 (load factors), 6A.4.4.2.3 (legal load factor), 6A.4.5.4 (permits), 6A.6.4.2.2 (Service II for steel). Load factor tables as corrected in AASHTO-MBE-3-ERRATA p.24.
- AASHTO LRFD BDS 8th Ed., 3.6.1 (HL-93), 4.6.2.2 (distribution factors), 6.10.7 (flexural resistance), 6.10.9 (shear).
- VDOT IIM-S&B-86.5 p.3 (rating vehicles), p.5 (condition factor, plastic analysis); VDOT load rating guideline G2 p.1 (Virginia legal trucks).
- Examples 1–3 are illustrative: section properties, dead loads and distribution factors were worked out for these sections, not taken from real bridge files.
A study aid, not a substitute for the AASHTO MBE or an agency's rating procedures. Example numbers are illustrative.