Steel girder in shear
A thin web carries shear until it buckles. With stiffeners on both sides it keeps going after that, as a diagonal tension band held by the flanges and stiffeners. The sheet finds how much of each the web can give.
Key points
- C is the share of yield the web reaches before it buckles. Stocky webs yield (C = 1). Slender webs buckle first, and in the elastic range C falls with the square of D/tw.
- Stiffeners help twice. Closer spacing raises k and so the buckling strength. In an interior panel they also let a tension field form after buckling, up to the equation above.
- The flanges must anchor the band. If 2Dtw / (bfctfc + bfttft) is over 2.5, only a reduced tension field counts.
- End panels and unstiffened webs get no tension field. Their strength is C Vp. A panel with stiffeners more than 3D apart counts as unstiffened.
- Web loss at the girder end is expensive. The shear is highest there, and a slender web's buckling strength goes roughly as tw³. Measure the remaining web carefully.
Poor condition uses φc = 0.90. New girders have no longitudinal web stiffeners, so D/tw ≤ 150, and transverse stiffeners are used only where they pay for themselves; a bolted splice counts as one. Ratings are run in AASHTOWare BrR with VDOT's control settings, which include whether stiffened end panels get tension field. VDOT IIM-S&B-86.5 §11.1 VDOT-MOSB-P2-C11 p.21 VDOT-LR-G6 p.24
Quick check
A slender web, in elastic buckling, loses 10% of its thickness. Its buckling strength C Vp drops by about…
Vp goes with tw and C with tw², so 0.9³ = 0.73. Try it on Example 2 by changing tw.
An unstiffened web gets stiffeners at do = D. The buckling coefficient k goes from 5 to…
k = 5 + 5/(do/D)² = 5 + 5 = 10. The square-panel web is twice as hard to buckle.
Why does a stiffened end panel get no tension field?
The tension field pulls on the panel next to it. At the girder end there is nothing outboard, so the end panel works as the anchor for the next panel instead.
Sources
- FHWA-NHI 130092, LRFR participant workbook, Lesson 20 (pp. 655–680); the workbook check is the exercise on PW 20.12–20.23, solution pp. 839–841.
- AASHTO LRFD BDS 8th Ed., 6.5.4.2 (φv = 1.0), 6.10.2.1.1 (web proportions), 6.10.9 (shear resistance).
- AASHTO MBE 3rd Ed., 6A.4.2 (rating equation; φs = 1.0 for shear, Table 6A.4.2.4-1).
- VDOT IIM-S&B-86.5 §11.1 (condition factor); S&B Manual Part 2, Chapter 11, p. 21 (stiffeners); VDOT Load Rating Guideline G6, p. 24 (BrR control options).
A study aid, not a substitute for the AASHTO MBE or an agency's rating procedures. Example numbers are illustrative.