Steel girder in bending
In positive bending the deck holds the top flange, so a composite steel girder cannot buckle sideways. Its strength is the moment when the whole section has yielded: find where the deck and the steel balance, and the rest follows.
Key points
- The PNA is where the forces balance. Deck at 0.85f′c, every steel part at Fy. Most rolled beams and many plate girders have it in the deck; a narrow deck or a heavy bottom flange pushes it into the steel.
- No sideways buckling here. The deck braces the top flange all along, so lateral-torsional buckling does not apply in positive bending. It does over a pier, and for a girder before the deck is cast.
- Compact means it may yield fully. Straight girder, Fy ≤ 70 ksi, D/tw ≤ 150 and not too much web in compression. Otherwise the strength is a flange stress, not a moment. Curved and kinked girders are always noncompact.
- Ductility protects the deck. A deep PNA means the deck must strain a lot before the steel is fully yielded. The 1.07 − 0.7Dp/Dt rule takes off a margin for that, and beyond 0.42 the section is not allowed.
- Service II is a second check. It limits the elastic flange stress to 0.95Fy (composite), with no resistance factors, to stop permanent sag under heavy trucks. It often governs compact sections.
New steel superstructures, and steel superstructures fully replaced above the substructure (projects started after November 16, 2018), may not be rated with plastic analysis; use the elastic flange-stress method (Lesson 21). The haunch is not counted for strength, and longitudinal web stiffeners are not used, so D/tw ≤ 150 always applies. VDOT IIM-S&B-86.5 §11.2 VDOT-MOSB-P2-C11 pp.9, 21
Quick check
The PNA is in the deck. You raise the deck strength from 3 to 4 ksi. The depth to the PNA…
Ȳ = ΣPsteel / (0.85f′cbs): a stronger deck balances the steel with less depth. Try it on Example 1 by changing f′c.
A compact section has Dp/Dt = 0.30. What share of Mp may you use?
1.07 − 0.7 × 0.30 = 0.86. It is past the 0.10 threshold but within the 0.42 limit.
Example 2 is a 2021 replacement. For a VDOT rating, which strength do you start from?
Virginia does not allow plastic analysis for new or fully replaced steel superstructures, so the compact Mn is not the capacity to use.
Sources
- FHWA-NHI 130092, LRFR participant workbook, Lesson 19 (pp. 619–654); the workbook check is MBE Example A1 (PW 19.20–19.28).
- AASHTO LRFD BDS 8th Ed., 6.10.4.2.2 (Service II), 6.10.6.2.2 (compactness), 6.10.7.1.2 and 6.10.7.3 (nominal resistance, ductility), Appendix D6, Table D6.1-1 (plastic moment).
- AASHTO MBE 3rd Ed., 6A.6.4.2.2 (Service II rating of steel).
- VDOT IIM-S&B-86.5 §11.2 (no plastic analysis for new steel); S&B Manual Part 2, Chapter 11, pp. 9 and 21 (composite design, haunch, no longitudinal stiffeners).
A study aid, not a substitute for the AASHTO MBE or an agency's rating procedures. Example numbers are illustrative.