Moment strength of concrete members
The steel pulls, the concrete at the top pushes back, and the moment is that pull times the distance between them. The sheets below find that moment for prestressed and reinforced sections, then check that the member has enough steel to give warning before it breaks.
Sheet 2 · Minimum steel, service limits and the rating
Take φMn from Sheet 1. This sheet checks that the member will not snap at the first crack, gives the service stress limits, and rates it for HL-93.
Key points
- The steel sets the moment. In a normal bridge member the bars yield, or the strands get close to fpu. The concrete only has to balance that pull, so the block is thin and the lever arm is nearly the full depth.
- Check where the block sits. If a is no deeper than the flange, the section works as a rectangle as wide as the flange. If it is deeper, use the T-section equation. For a composite girder, the concrete in compression is the deck.
- The strain sets φ. At 0.005 or more in the lowest steel the section is tension controlled (φ = 1.0 prestressed, 0.90 reinforced). Less strain means less warning, and φ falls toward 0.75. Too much steel costs φ.
- Minimum steel protects against a sudden break. If the member cannot carry its own cracking moment once cracked, the first crack is the failure. The MBE does not throw the member out: it multiplies the strength by K = φMn / min(Mcr, 1.33Mu) ≤ 1.
- Prestressed members also have stress limits. Service III limits the bottom tension under traffic; Service I keeps the steel below 0.9 of yield under permit loads. Losses lower the first, but hardly change the strength.
Prestressed members are rated on the gross section, with losses by the AASHTO approximate method (the refined method if the ratings come out low or the member is noncomposite). The condition factor is 1.00 for Fair and better and 0.90 for Poor. IIM-S&B-80.10 does not change the flexure articles (LRFD 5.6.2, 5.6.3). VDOT IIM-S&B-86.5 p.5, Table 2; IIM-S&B-80.10
Quick check
On Sheet 1, Example 1, double the strands from 28 to 56. What happens to Mn?
The block gets deeper (a ≈ 6.8 in., still inside the deck), so the lever arm shrinks and the strand stress drops a little, to about 257 ksi. Mn goes from about 4,350 to 8,200 k-ft, 1.9 times. The strain is still about 0.015, so φ stays 1.0.
The losses turn out 20 ksi higher than assumed. The girder's Mn…
The strand stress at failure, fps, does not depend on the losses as long as fpe stays above 0.5fpu. What does fall is the precompression, so the cracking moment and the Service III limit go down. Try it on Sheet 2.
Two beams have the same Mn. One has a steel strain of 0.010 at failure, the other 0.003. Why does the second get a lower φ?
φ rewards warning. A section whose steel stretches a lot cracks and deflects visibly before it fails. One with low steel strain crushes suddenly, so the code keeps a bigger margin.
Sources
- FHWA-NHI 130092, LRFR participant workbook, Lesson 13 (pp. 431–470); walk-through PW 13.18–13.32.
- AASHTO LRFD BDS 8th Ed.: 5.5.4.2 (resistance factors), 5.6.2.1 and Table C5.6.2.1-1 (strain limits), 5.6.2.2 (stress block), 5.6.3.1.1 and 5.6.3.2.2 (c, fps, Mn), 5.6.3.3 (minimum reinforcement), 5.4.2.6 (fr), Table 5.9.2.3.2b-1 (tension limit).
- AASHTO MBE 3rd Ed.: 6A.5.6 (K factor), 6A.5.4.2.2 (Service I), Table 6A.4.2.2-1 (limit states and load factors), 6A.4.2.3 (condition factor).
- VDOT IIM-S&B-86.5, p.5 and Table 2 (gross section, losses, condition factor); IIM-S&B-80.10, pp.6, 8 (concrete classes and losses for new design).
A study aid, not a substitute for the AASHTO LRFD, the MBE or an agency's rating procedures. Example numbers are illustrative.