Sign in
LRFR · Lesson 13

Moment strength of concrete members

The steel pulls, the concrete at the top pushes back, and the moment is that pull times the distance between them. The sheets below find that moment for prestressed and reinforced sections, then check that the member has enough steel to give warning before it breaks.

Sheet 2 · Minimum steel, service limits and the rating

Take φMn from Sheet 1. This sheet checks that the member will not snap at the first crack, gives the service stress limits, and rates it for HL-93.

Key points

Mn ≈ T (d − a2),   T = Apsfps + Asfs
  • The steel sets the moment. In a normal bridge member the bars yield, or the strands get close to fpu. The concrete only has to balance that pull, so the block is thin and the lever arm is nearly the full depth.
  • Check where the block sits. If a is no deeper than the flange, the section works as a rectangle as wide as the flange. If it is deeper, use the T-section equation. For a composite girder, the concrete in compression is the deck.
  • The strain sets φ. At 0.005 or more in the lowest steel the section is tension controlled (φ = 1.0 prestressed, 0.90 reinforced). Less strain means less warning, and φ falls toward 0.75. Too much steel costs φ.
  • Minimum steel protects against a sudden break. If the member cannot carry its own cracking moment once cracked, the first crack is the failure. The MBE does not throw the member out: it multiplies the strength by K = φMn / min(Mcr, 1.33Mu) ≤ 1.
  • Prestressed members also have stress limits. Service III limits the bottom tension under traffic; Service I keeps the steel below 0.9 of yield under permit loads. Losses lower the first, but hardly change the strength.
In Virginia

Prestressed members are rated on the gross section, with losses by the AASHTO approximate method (the refined method if the ratings come out low or the member is noncomposite). The condition factor is 1.00 for Fair and better and 0.90 for Poor. IIM-S&B-80.10 does not change the flexure articles (LRFD 5.6.2, 5.6.3). VDOT IIM-S&B-86.5 p.5, Table 2; IIM-S&B-80.10

Quick check

On Sheet 1, Example 1, double the strands from 28 to 56. What happens to Mn?

The losses turn out 20 ksi higher than assumed. The girder's Mn…

Two beams have the same Mn. One has a steel strain of 0.010 at failure, the other 0.003. Why does the second get a lower φ?

Sources

A study aid, not a substitute for the AASHTO LRFD, the MBE or an agency's rating procedures. Example numbers are illustrative.